In many applications it is convenient to have a compact waveguide load which is well matched but occupies a minimum of space. In this memo we describe measurements on compact WR-10 and WR-3.7 waveguide loads of three configurations, and also Fourier transform spectrometer (FTS) measurements on samples of the Eccosorb MF-112 and MF-116 absorbing materials used for these loads. The measurements were made at room temperature and 4 K. From the FTS measurements, the attenuation constant, effective characteristic impedance and effective dielectric constant in the frequency range 400 GHz -2.5 THz are deduced.
View a pdf version of ALMA Memo #494.
Last modified: 2004-05-18