L. D'Addario [1]
May 19, 1999
Keywords: cryogenics, SIS Mixers, Receivers, cryocoolers, Joule-Thompson
Presented here are outlines of two designs for cryocoolers that might be used with the MMA/ALMA SIS mixer receivers. We concentrate mainly on the last stage of cooling, which in both cases is a Joule-Thompson expander. The first case is the current, preliminary design (further discussed in [1]), intended to provide 0.7 W of cooling at 4.0K at the mixer mounting plate. The second is intended to provide 0.7 W of cooling at 2.5K. For comparison, some data is also presented on the 4K, 1.5 W coolers now used at the NRAO 12m telescope and elsewhere.
[1] NRAO-TUC
View a PDF version of MMA Memo #266.
View a text version of MMA Memo #266.Download a 6.8kB gzipped postscript version of MMA Memo #266 from
Last modified: 1999-dec-09